{"en":"NCF-EC Series EC-Tech Forced Draft Closed Cooling Tower","zh-cn":"EC节能型强制通风闭式冷却塔NCF-EC系列"}

NCF-EC Series EC-Tech Forced Draft Closed Cooling Tower

NCF-EC Series EC-Tech Forced Draft Closed Cooling Tower

NCF-EC
EC-Tech Forced Draft Closed Cooling Tower
Normal Model: NCF-EC
Cooling Tower Type: Counter flow closed circuit cooling tower
Air Ventilation: Forced draft via EC-Tech centrifugal fan drive system
Cooling Mode: Wet cooling mode

Heat Exchanger: Stainless Steel Heat Exchange Coil
Cooling Tower Body: Z700 galvanized casing ( SUS304/316 or NWN-Armour anti-corrosion coating steel plate for option)

NCF-EC Series EC-Tech Forced Draft Closed Cooling Tower

NEWIN NCF-EC series is a groundbreaking modular open-type cooling tower. By integrating a centrifugal EC smart fan system, forced draft technology, and Armour anti-corrosion upgrades, it not only innovates upon the classic counter-flow open design but also significantly enhances equipment adaptability and operational reliability under complex working conditions.


 

ADVANTAGES


> Smart & Energy Efficient: The EC centrifugal fan features built-in automatic frequency conversion, offering high energy efficiency and low-noise operation.

> Highly Efficient Heat Dissipation: Combines forced draft with counter-flow design for stable heat exchange, particularly suitable for large temperature difference scenarios.

 

140x140

 


140x140





> Robust & Durable: Constructed with Armour anti-corrosion steel plate, providing strong corrosion resistance and extended equipment lifespan.

> Compact Structure: Modular design requires a small footprint, allows flexible layout, and features an aesthetically pleasing appearance.

> Strong Adaptability: Effectively handles challenging environments such as poor ventilation and inferior water quality, ensuring high reliability.

 


 


EC- GREEN TECH Applicated In Cooling Tower


Multiple EC Centrifugal Fans Design
> Multiple EC centrifugal fans can provide improved and uniform air extraction, ensuring air flow fully through the heat exchange coils, resulting in wider coverage and enhanced thermal efficiency.
> The forced draft fan drive is capable of providing long-distance air supply, making it particularly suitable for poorly ventilated areas.

Operational Redundancy Option
> When multiple fans are operating in parallel, if one fan malfunctions, the remaining fans can compensate for the loss of airflow by increasing their speed. Additionally, the replacement process for a malfunctioning fan can be carried out swiftly while the tower is still in operation.
> Redundancy advantage is one of the advantages of EC fan systems compared with AC fan systems.

140x140

 

Counter Flow Closed Type System
 


> The forced action of the fan facilitates the easy entry and passage of air flow through the stainless steel heat exchange coil, resulting in a counter-flow to the water flow, thereby maximizing contact and enhancing heat exchange efficiency.

> The closed type system, utilizing the stainless steel heat exchange coil for the circulation of the cooling medium and achieving cooling through wall-type heat exchange between spray water and the coil, ensures media purity, reduces maintenance costs, and conserves valuable water resources while providing efficient cooling.
 


About Other Main Parts
 

300x200
Advanced Fan Drive System -EC Centrifugal Fan

Perfectly matched components (controller/motor/PP impeller)
> The enhanced impeller technology and new EC motor lead to a substantial increase in efficiency, resulting in energy savings of 30%~40% compared to general centrifugal fans.
> The new motor in GreenTech EC technology with integrated control electronics;
> High power density; Robust design and maintenance-free operation; Easy initial set-up.
> EC Motor: Degree of protection: IP55, Insulation class : F, Super Premium Efficiency is up to IE5. 

300x200
PVC Heat Exchange Layer

> The PVC heat exchange layer is composed of the cellular type fill blocks, which are highly resistant to pressure drop. The specially crafted fill sheets create a systematic and compact fluid channel once they are bonded together. 
> As multiple layers of filler blocks are stacked, the water spray area expands, facilitating complete contact between water and air in order to enhance heat exchange efficiency.

300x200
Cellular Type Easy-to-detach PVC Drift Eliminator

> Efficiently extracting airborne water droplets, small wind resistance and an impressive capture rate of 99.99%, thus guaranteeing optimal heat transfer performance.

300x200
Uniform Water Distribution

> The strategically positioned ABS Three-splashed-Nozzles, evenly water distribution under low pressure flow; Large caliber and three splashed type design, not easy to block, enhance spray coverage and guarantee continuous effective spraying, ensuring the efficient cooling performance of cooling tower.

 

Optional Various Additional Functions
Two-speed& VFD variable frequency motor/ Vibration Cut-off Switch/ Electronic descaler/ Water treatment equipment/ Anti-freeze automatic heating system/ Noise reduction upgrade/ External maintenance platform and guardrail/Installation and maintenance boom etc.
 


140x140


Cost-effective Anti-Corrosion Solution

NWN-Armour Anti-corrosion Technology
Products coated with NWN-Armour anti-corrosion coating exhibit outstanding resistance to corrosion, approaching the qualities of stainless steel. They serve as a cost-effective alternative to stainless steel.
 




Reference Projects


300x200

Rockwool Plant Project 

> NCF-EC series cooling tower- NEWIN cooling solution for Rockwool plant project in Russia.

300x200

Rockwool Plant Project 

> NCF-EC series cooling tower- NEWIN cooling solution for Rockwool plant project in Russia.

Please make sure your contact information is correct. Your message will be sent directly to the recipient(s) and will not be publicly displayed. We will never distribute or sell your personal information to third parties without your express permission.

Related Products